Infrared garage heaters
Model pick · spec-based
Dr. Infrared DR-238 1,500W carbon infrared heater (wall or ceiling)
For one bay or a workbench on a 120 V outlet with nothing else on that circuit: 1.5 kW carbon infrared. It mounts high, so check your ceiling height first.
Paid links: we earn a commission if you buy through links on this page, at no cost to you. As an Amazon Associate, BayHeat earns from qualifying purchases.
Check price on AmazonManual: the lowest part of the heater must be at least 94.5 in above the floor, wall or ceiling mounted, and a wall mount needs 15.8 in to the ceiling, so check your ceiling height first; a standard 8 ft ceiling will not meet it. Not where gasoline, paint or flammable liquids are used or stored. Plug it straight into the outlet: never an extension cord or power strip. Do not leave it unattended when in use. Source ↗
Radiant (infrared/quartz) heat warms people and surfaces directly, so it still feels warm right where the door is open or a draft cuts across the floor. Forced-air heats the room's air, which a big door opening or a leaky envelope keeps flushing outside. A drafty shop or a bay with the door up often does better on radiant; a fully enclosed garage that needs even heat throughout does better on forced-air.
Why the door matters more than the wattage
A forced-air heater — a 240V fan-forced unit or a vented gas unit heater — raises the temperature of the air in the room, then relies on that warm air staying put. Open a Computed by our engineEXAMPLE_A_INPUT.garageDoors[0].w — lib/planner/fixtures.tsReport a problem garage door and the air it just heated leaves in minutes; the heater keeps working against a load the planner's Computed by our engineheatLossDesign() on EXAMPLE_A_INPUT — garage_doors share of design loadReport a problem door-loss share already accounts for.
A radiant heater skips that step. It heats the person, the workbench, and the slab under your feet by direct infrared, the same way sunlight warms your arm on a cold day before it warms the air around it. Cut the air moving and the heat still lands.
The comfort-equivalent assumption
BayHeat's planner models this as a labeled assumption, not a logged result: because radiant output reaches people and the slab directly, it treats radiant heat as feeling like forced-air heat run about An estimate, labeled as an assumptionplanner-engineering.md §7, radiant comfort-equivalent assumption: target − 5°F for radiant, applied in lib/planner/heatLoss.tsReport a problem warmer than the thermostat reading. On BayHeat's standard worked example — a 24×24 ft attached 2-car garage in Chicago — holding Computed by our engineEXAMPLE_A_INPUT.targetTempReport a problem by forced-air feels comparable to holding about An estimate, labeled as an assumptionEXAMPLE_A_INPUT.targetTemp − 5°F comfort-equivalent assumptionReport a problem of radiant air temperature — nobody has logged this with a thermal-comfort survey in this garage, so treat it as a modeled estimate, not a measurement.
The two radiant classes on the market
Both run on electric resistance, so neither needs venting — the tradeoff is coverage area, not combustion safety.
Paid links: we earn a commission if you buy through links on this page, at no cost to you. As an Amazon Associate, BayHeat earns from qualifying purchases.
120V WALL INFRARED · 1.5 KW
Heat Storm HS-1500-TT
From a manual or spec sheetHeat Storm Tradesman HS-1500-TT owner's manual · checked 2026-09-25Report a problem (Computed by our engineHEATER_CLASSES.e_ir_wall_1500.outputBtuh — lib/planner/catalog.tsReport a problem–Computed by our engineHEATER_CLASSES.e_ir_wall_1500.outputBtuhReport a problem) on an existing 120V outlet, mounted at From a manual or spec sheetHeat Storm Tradesman HS-1500-TT owner's manual · checked 2026-09-25Report a problem or higher. Sized for a workbench or one bay, not a whole garage.
Manual: not where gasoline, paint or flammable liquids are used or stored.
Or the Dr. Infrared DR-238 (From a manual or spec sheetDr. Infrared Heater DR-238 carbon infrared heater owner's manual · checked 2026-09-30Report a problem, mounts at From a manual or spec sheetDr. Infrared Heater DR-238 carbon infrared heater owner's manual · checked 2026-09-30Report a problem or higher): Check price on Amazon ↗
Manual: the lowest part of the heater must be at least 94.5 in above the floor, wall or ceiling mounted, and a wall mount needs 15.8 in to the ceiling, so check your ceiling height first; a standard 8 ft ceiling will not meet it. Not where gasoline, paint or flammable liquids are used or stored. Plug it straight into the outlet: never an extension cord or power strip. Do not leave it unattended when in use.
Price class: $
240V QUARTZ/TUBE CEILING · 3–6 KW
240V infrared ceiling heater
Computed by our engineHEATER_CLASSES.e_ir_240.outputBtuh — lib/planner/catalog.tsReport a problem–Computed by our engineHEATER_CLASSES.e_ir_240.outputBtuhReport a problem on a Computed by our engineclassCircuit(HEATER_CLASSES.e_ir_240) — lib/planner/classCircuit.tsReport a problem, Computed by our engineclassCircuit(HEATER_CLASSES.e_ir_240).breakerA: 125% of its 6 kW top (NEC 424.4(B))Report a problem circuit. Aimed down from a high ceiling, it's built for a drafty shop or a bay that runs with the door up, not a sealed, evenly heated room.
Keep clearances below the heating element per the manual -- radiant elements ignite anything left underneath.
Price class: $$
Where radiant alone falls short
- Why not a 240V quartz/tube infrared ceiling heater (3-6kW)? A fully enclosed, occupied garage that needs even heat throughout — a finished workshop you sit in for hours — is better served by forced-air or a mini-split. Radiant only warms what's in its direct line of sight; the far corner of a closed room stays cold under a spot infrared element.
Radiant panels also do nothing for the air itself, so a garage that needs to keep tools, paint, or stored goods above a minimum temperature — not just a person working in it — needs forced-air or a heat pump instead.
Safety
Both classes are electric resistance, not combustion, but a radiant element runs hot to the touch and aims heat outward on purpose. Keep the manual's clearance from anything flammable, and never aim one at a vehicle's fuel fill or a gasoline can. A 120V unit still needs GFCI protection on the outlet it plugs into (A code or reference citationNFPA 70, National Electrical Code, 2023 · checked 2026-09-25Report a problem). Your electrician and your local code edition govern.
For a garage sized from your own dimensions, run the garage heater calculator →. For every wall-listed electric class side by side, see wall-mount garage heaters →.
Related
Shop heaters
Compare 240V electric, vented gas and diesel shop heaters by circuit, vent and CO rule, and see why a torpedo heater doesn't belong in a closed shop.
Size chart
Wattage brackets for 1-, 2-, 3- and 4-car garages by insulation and climate — a planning bracket, not a load calculation.
Best picks
Garage heater picks by situation, chosen from manufacturer specs and our load model: plug-in, hardwired ceiling, infrared, vented gas and mini-split.
Electric
Every electric garage heater class from a 1.5 kW plug-in to a 10 kW ceiling unit, and the exact circuit each one needs.
Sources
- [1] Heat Storm Tradesman HS-1500-TT owner's manual, Heat Storm. Retrieved 2026-09-25.
- [2] Dr. Infrared Heater DR-238 carbon infrared heater owner's manual, Dr. Infrared Heater. Retrieved 2026-09-30.
- [3] NFPA 70, National Electrical Code, 2023, NFPA. Retrieved 2026-09-25.