Mini-split for a garage

A 12-24k class mini-split heat pump runs about $3,000–$7,000 installed, against about $750–$1,700 for a plain 240V resistance heater sized to the same garage. In a sealed 2-car garage in Chicago, the heat pump's lower running cost usually closes that gap inside 5 years — and unlike the resistance heater, it also cools.

Model pick · spec-based

Della Optima 12,000 BTU 230V mini-split heat pump (heat + cool)

One 12,000 BTU/h 230 V heat pump that heats and cools. The refrigerant work needs a licensed HVAC contractor.

Paid links: we earn a commission if you buy through links on this page, at no cost to you. As an Amazon Associate, BayHeat earns from qualifying purchases.

Check price on Amazon
Paid link

Refrigerant work (vacuum, charge, line-set brazing) needs EPA Section 608 certification -- have it installed by a licensed HVAC contractor. Source ↗

The real seasonal COP, not the nameplate number

A mini-split's rated output is set at a 47°F outdoor temperature — not a Chicago January night. As the outdoor temperature drops, both its capacity and its coefficient of performance (COP, heat delivered per unit of electricity) fall. At this garage's design temperature, a standard-class unit rated for can only deliver about at a COP of about . A cold-climate/hyper-heat model holds up better — about at the same outdoor temperature.

Bin-integrated over a whole heating season in this sealed garage (qDesign about , grade B), a standard-class unit averages a season-wide COP of about ; cold-climate averages about . Both numbers already include the resistance backup that kicks in whenever the compressor can't keep up — that's normal, not a malfunction.

On the coldest nights, a standard-class unit still only covers about of this sealed garage's design load; cold-climate gets to about . Either way, check the manufacturer's low-ambient capacity curve against your own design temperature before assuming the nameplate BTU number is what you'll actually get in January.

5-year cost: heat pump vs. a plain resistance heater

Same sealed garage, same seasonal load, two ways to cover it — a 12-24k mini-split heat pump, or a right-sized 7.5 kW electric resistance heater:

SystemInstalledSeason, running5-year total
Mini-split heat pump (Mini-split heat pump, 12-24k class (230V))$3,000–$7,000$628$8,142 at mid-range install
Electric resistance (240V shop heater (7,500W))$750–$1,700$1,578$9,115 at mid-range install

Savings vary. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power.

At the midpoint of each install range, the heat pump comes out several hundred dollars ahead over 5 years of running cost alone — before counting cooling. But installed price is the real swing factor: at the cheap end for resistance and the expensive end for the heat pump, resistance wins outright. Get an actual installer quote before treating either total as settled.

Also runs backward: cooling

The same outdoor/indoor unit reverses in summer to cool the garage — useful if it doubles as a shop, gym or hangout space in July. BayHeat's cooling load calculator isn't live yet, so this page doesn't quote a cooling BTU/h or a summer running cost; treat the cooling capability as a real feature of the equipment, not a number to plan around until that calculator ships.

Why not sealing skips this

This whole comparison assumes the garage is sealed first. The as-is version of the same 24×24 garage (R-13 walls, one uninsulated steel door, average drafts) needs about — a nameplate only covers about of that, before any cold-weather derate. Seal the envelope first, then size the heat pump to what's left.
  • Why not a DIY pre-charged mini-split, 12k class (115V)? A DIY pre-charged 115V mini-split tops out around 12,000 BTU/h on a shared 120V/20A circuit — enough for a small, already-sealed 1-car bay, not this comparison's 2-car load, and it skips the licensed refrigerant charge check most manufacturers require for warranty.

Paid links: we earn a commission if you buy through links on this page, at no cost to you. As an Amazon Associate, BayHeat earns from qualifying purchases.

MINI-SPLIT HEAT PUMP · 12-24K CLASS · 230V

Della Optima 12,000 BTU 230V mini-split heat pump (heat + cool)

Heats and cools on a dedicated circuit. Refrigerant work needs a licensed HVAC contractor — see the safety note below.

Refrigerant work (vacuum, charge, line-set brazing) needs EPA Section 608 certification -- have it installed by a licensed HVAC contractor.

Price class: $$$$

Safety: GO · PER MANUAL

No combustion, no CO risk from the heater itself — the conditions here are about the install, not the fuel.

  • Sized and installed by a licensed HVAC contractor -- refrigerant work needs EPA Section 608 certification. (40 CFR Part 82)
  • Check the manufacturer's low-ambient heating capacity curve against your design temperature -- the nameplate BTU rating is measured at 47°F, not at your coldest night. (Manufacturer manual)

General information. Your electrician, gas fitter, local code and the heater's manual govern.

Next step

Run your own garage through the planner → to see whether it's sealed enough for a mini-split to actually cover the coldest night, or whether fixing the envelope first gets you there for a lot less money.